Filter Results By:
Products
Applications
Manufacturers
Voltage Transformer
a type of intrument transformer enabling secondary connected metering.
- Pickering Interfaces Inc.
product
LXI High Voltage Matrix 2-Pole 100x2
60-310-102
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing. The 60-310 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
product
Quasi Square Wave Constant Voltage Transformers
Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.
-
product
Dielectric Withstand Tester
Weshine Electric Manufacturing Co., Ltd
The induction withstand voltage test of transformers and transformers is an important test to ensure that the quality of transformers conforms to national standards. The longitudinal insulation induction withstand voltage test of the inter-turn, inter-layer, inter-section and inter-phase insulation of the transformer winding is an important item in the transformer insulation test.
-
product
Partial-discharge Detection System
GDYT Series
GDYT series include partial discharge power frequency testing transformer(YDTW),partial discharge detector(GDJF2008),Isolation filter frequency doubling power device(GDSF-81G) and power frequency withstand voltage control table(GDYD table).It widely used in electrical manufacturing,power operation departments, research institutes and universities.
-
product
Tan Delta Test System
Precision measuring bridge is designed for determining the capacitance and dielectric dissipation factor of liquid and solid insulants, cables, capacitors, line transformers, generators, motors, bushings etc. Furthermore it can also be used for power loss measurement on shunt reactors or similar apparatus. This system is suitable for both low and high voltage measurement at line frequency. Measurement reports can be printed. This measuring equipment has been specially developed to maximise efficiency in production and quality control environments. Its outstanding accuracy also makes it suitable for laboratory and research applications.
-
product
Variable Frequency Series Resonance Test Device
WABP
Wuhan Sangao Electrical Test Installations Limit Co.
The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.
-
product
Transformer Degaussing Analyzer
KRI6691
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
product
ACDC
EA Series
The EA Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
product
High Impedance Differential Module
HID
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
3 Phase Voltage Extension To Turns Ratio Meter Rack
T-REX R
The Raytech three phase voltage system option T-Rex R is an optional system accessory for 3- Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III R). T-Rex R was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase
SL1201A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Multifunction Substation Test Set
STS 4000
STS 4000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers, designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.
-
product
Advanced Handheld Partial Discharge Detector for Electric Power Equipment with Multi-Sensor and Cloud Diagnostic Technologies, Data Management Software, and Test Management App
PDetector
Power Monitoring and Diagnostic Technology Ltd.
The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF), Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis. The PDetector greatly simplifies and standardizes the routine OLPD testing procedure by using the Intelligent Patrol function, the PDetector App, and the PMDTCloud. It is a very powerful and helpful tool for substation operators to conduct routine testing in a substation quickly, to determine what the issue is, and where it is located.
-
product
Insulation Resistance Tester
BC2010 / 751
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for measuring cable, motor, generator, transformer, transformer, high voltage switch, lightning arrester and so on.
-
product
Gas-Filled Hv Testing Transformer
GTU-300KVA/600KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
product
Regenerative AC Emulator, 1200 VAC, 65 A, 90 KVA, 3‑Phase
SL1213A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
Turns Ratio Meter 3 Phase
TR-MARK III 250V
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase
SL1202A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Digital Insulation Resistance Tester
HT2565 / 773
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for measuring insulation resistance of large capacity transformer, transformer, generator, high voltage motor and lightning arrester.
-
product
Transformer Turns Ratio Meter
TTRM 301
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
Partial Discharge Test Set
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
product
Precision Multirange Current Transformer
P-2000
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
product
Automation
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
product
Inflatable High Voltage Testing Transformer
GTU-250KVA/500KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
product
Transformer Power Tester
HDFZ -III
HD Power Test Equipment Co.ltd
HDFZ-III Transformer Power Tester is an multi-function instrument which is used to test accurately a serious of parameters such as capacity, type, no-load current ,no-load loss, impedance voltage of various transformers. The test result of capacity and characteristic can be up to 100% accuracy rate. The capacity measurement range :10kVA~100000kVA。
-
product
Power Quality Analyzer
PQM-700
*power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V, with particular emphasis on measurements at low voltage poles, due to the ease of connection,*has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits,built-in real-time clock.
-
product
LV Iron Core Shunt Reactors
Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.
-
product
AC Voltage Test Systems
HIGHVOLT Prüftechnik Dresden GmbH
AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.