Filter Results By:
Products
Applications
Manufacturers
Safety Jacks
Socket whose insulating jacket meets safety standards.
- Virginia Panel Corporation
product
VTAC Patchcord, Receiver, 72", VTAC, 2x 1000Base-T1 UTP wire H-MTD Cable Jack, 1 Slot
7-142716765-072
VTAC Patchcord, Receiver, 72", VTAC, 2x 1000Base-T1 UTP wire H-MTD Cable Jack, 1 Slot.Note: Static Bend Radius - 19.2mm [.76in], Flex Bend Radius - 48mm [1.89in]
-
product
Magnetizer
340B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
Deluxe DMM w/Amp Shutters
582
*Huge 2 inch LCD Display, easy to see from across the room *Display is backlit for use in Dark Spaces *Amp Shutters prevent mistaken operation, improve safety and saves fuses by blocking unused amp jacks! *Great Meter for Electrical Trouble Shooting *11 Test Functions, 33 Test Ranges *Measures Temp in Both F and C, Probe Included *Desireable 20 Amp Test Range *Modern Design, the Protective Holster is Built-In *Data Hold *Carrying case, Test leads, Temp probe, Instructions and Battery included
-
product
Magnetizer
350B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781028-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
Air Force
Alpha 4314 AF
4314AF introduces an added safety feature that prevents the possibility of having the charging adapter connected while using the instrument for measurements. A 6-pin Mil-Spec circular connector on the front panel of the 4314AF replaces the four-terminal banana jacks and the battery charger jack. Four of the front panel connector pins are used to mate with the measurement adapter cable and the other two pins are for the battery charging cable adapter. By using separate adapter cables for measurements and charging of the batteries, it ensures that the charge circuit cannot be activated at the same time as measurements are being made.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
Magnetizer
330B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781209-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
High Voltage Switching Systems
HXV Series
HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.
-
product
IEC61032 Test Probe Pin
CX-112
Shenzhen Chuangxin Instruments Co., Ltd.
1. Jointed test finger probe (Figure 2 / Test Probe B / IEC 61032)This is a precision probe made in accordance with all IEC standards. Examples are IEC 61032, 60950, 61010 and 60601; and it is also used for Canadian and USA standards. It features a palm simulator and a restricted joint movement, which simulates the characteristics of the human hand. The finger is made of stainless steel and the rest of the instrument is Delrin®. Handle is designed to accept either a banana jack or a force gauge.It is no longer necessary to have a separate probe for the medical safety standard. This one probe will meet all the different requirements that are in the IEC standards.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-02
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
Power Control
Educated Design & Development, Inc.
As a general purpose dual-voltage isolation transformer for step-up (120 to 240 VAC), step-down (240 to 120 VAC), or straight 1:1 isolation (120 to 120 VAC or 240 to 240 VAC). Models with a suffix "UC" are provided with a safety jack for access to the transformer secondary center tap (connected to the transformer center tap only in the 240 VAC output setting). This connection may be used in conjunction with a Dielectric Voltage Withstand test.
-
product
Magnetizer
345B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Safety
Chroma Systems Solutions, Inc.
The purpose of safety testing medical electronic equipment is to be sure that a device is safe from electrical hazards to the patient and caregivers. There are a number of UL, European and Canadian standards that serve as the ruling body on how medical products will be tested, one in particular, IEC60601 (the International Electrical Safety Standard for medical electronic equipment) is experiencing “global harmonization,” meaning it has been accepted and implemented around the world. The IEC60601 standard is mainly intended for product development where safety considerations must be taken into account early in the design phase of a product, however much of it is applied to production line testing since it is the only way for a manufacturer to be sure they are shipping safe product.
-
product
Public Safety
Schnoor Industrieelektronik GmbH & Co. KG
Reliability, performance as well as quick, simple operation is of special importance in the range of public safety, police, fire brigades and rescue services. Schnoor Industrieelektronik develops radio systems, application and migration concepts, corresponding to the safety standard for Security Authorities and Organisations.
-
product
Electrical Safety Tester
MST-8101/8103
Multi-channel output is an internal high-voltage switching module attached at the bottom of the instrument. Through multi-channel output module, multiple test points of the components can be connected with multiple channels at a time. During testing, the instrument can be set to control the channel switch. Controllable testing can be achieved by connecting the corresponding port to withstand voltage test terminal. With this multi-channel module, rapid connection can be achieved through test fixture without changing ports during the testing process.
-
product
Safety Light Curtains
*Type 4 (IEC 61496) safety light curtains at Type 2 pricing*Reliable protection of hazardous areas*Short and long range selectable via wiring*No dead space when mounted in in L shape*Industry standard M12 connection for simple wiring
-
product
Safety Analysis
Ensure System Safety and Cybersecurity. Dramatically decrease analysis efforts with efficient application of quality, safety, reliability and cybersecurity analysis methods at the system, item, software, hardware and PCB levels.
-
product
Electrical Safety Analyzers
Built on the Vision Pad Platform, the vPad-ES Rugged is the ideal Electrical Safety Analyzer for Field Service Engineers.Housed in an Extreme Duty case, the vPad-ES Rugged offers the functionality and scalability that you have come to expect from Vision Pad Technology products plus the added assurance of knowing your system will be protected in the harshest of environments.
-
product
Electrical Safety Analyzer
Guarantee the safe operation of your electrical equipment with Netech’s Electrical Safety Analyzers. We offer three versatile electrical testing tools which can be used for a variety of safety testing on devices including hospital equipment and patient monitoring equipment. Scroll down to see an overview of our electrical safety analyzer models.
-
product
Functional Safety
More and more devices, machinery, plants and systems contain electrical, electronic and/or programmable electronic systems and components. Malfunctions – also in sub-systems and components – can lead to hazardous situations for people, machines and the environment. If these systems contribute to the safety of the product, it is necessary that they function correctly under all circumstances (including possible failures and malfunctions). One speaks of functional safety in this context.
-
product
Safety Products
This ACE product group provides Emergency braking to safely slow down moving loads and reduce damaging forces. Although the safety shock absorbers, TUBUS elastomer bumpers and clamping elements differ so much in design, every single ACE component provides the best protection for your machine.
-
product
Safety Shock Absorbers
As an alternative to the standard shock absorber, Safety shock absorbers are the tried and tested low cost method of preventing those occasional emergency stops. Designed for occasional use, they primarily serve as reliable, effective protection in emergency stop situations.
-
product
Ignition Safety Devices
Excelitas Technologies specializes in the design, manufacture, and testing of MIL-STD-1901A compliant rocket motor Ignition Safety Devices (ISD) for safe initiation of both launch and flight motor initiators. Our ISD designs are compatible with through bulkhead initiators that work in-line with the detonator to provide highly reliable transfer of pyrotechnic energy, while isolating the ISD from the rocket motor heat and combustion effects. Our ISDs are designed for either single- or multiple-pulse initiation applications.
-
product
Safety Voltage Detector
289 SVD
Standard Electric Works Co., Ltd
● Bright LED visual indication● Audible indication● Mute function● AC voltage detection: 100Vac ~ 69kVac● Frequency range: 50/60Hz● Easy-to-prove method● Self-test function● Power source: 1.5V(AA) alkaline battery × 3● Non-contact detection by proximity● Personal sensor, easy to wear and convenient to use● Can be attached with hot sticks by optional accessory● Lightweight, robust and compact● Easy access to batteries Comply with EN 61326-1
-
product
Safety Ohm Meter
Type 1681
Aeronautical & General Instruments Ltd.
The Type 1681 Safety Ohm Meter range are rugged highly portable intrinsically safe instruments for use in potentially Explosive Atmospheres. Six measurement ranges enable it to measure resistances from 1mΩ and 20kΩ using a 3½ digit backlit LCD display.
-
product
Electrical Safety Analyzers
Fluke Biomedical electrical safety analyzers provide accurate and reliable results, helping you meet your medical device testing and quality requirements while ensuring patient safety.
-
product
Charge System Safety
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
product
Electrical Safety Testers
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.