Filter Results By:
Products
Applications
Manufacturers
- Taylor Dynamometer, Inc.
product
622 HP Eddy Current Chassis Dynamometer
CM-51-EC
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 8,340 lb (3,783 kg)Capacity: 622 hp at 45 mph (464 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long4 front fixed rolls, 2 rear rolls fixed toaccommodate axle spreads from48 to 60 in. (1,219 to 1,524 mm)tandem centersPit Required Depth: 25 in. (635 mm)
-
product
Power Profiler, DC Energy Analyzer, Power Supply, Digital Multimeter, Source Measure Unit, Power Debugger
Otii Arc Pro
Otii Arc Pro is an instrument that can precisely source voltage or current and simultaneously measure voltage and/or current. It computes power and energy and syncs with software output, enabling engineers and developers to easily see what drains the energy and optimize the battery life of their devices under test.
-
product
Precision Source/Measure Unit (SMU)
B2900A Series
The Keysight B2900 Series precision source measure unit (SMU) provides superior performance and usability at a reasonable price. These compact benchtop SMUs enable you to quickly take various I-V (current versus voltage) measurements requiring high resolution and accuracy. Easily view results on the user-friendly, color LCD graphic interface without changing connections.
-
product
DC Power Supplies
SFA Series
AMETEK Programmable Power, Inc.
The SFA family builds on the industry leading Sorensen SGA series to provide a high power current source for laser diode applications. State of the art high power laser diodes require well-regulated current control to avoid catastrophic damage. Under anomalous operating conditions, excessive stored energy in the output circuit of the power supply can result in peak stresses that can permanently damage the device. Providing a constant current regulation mode only, the SFA’s low stored energy output minimizes damage potential for sensitive devices as well as enabling a current slew rate of up to 400 A/msec.
-
product
Near-Field Probes 100 kHz up to 50 MHz
LF1 set
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
product
High-Density Precision SMU (100 PA, 30 V)
PZ2130A
The Keysight PZ2130A is a high-channel density precision source / measure unit (SMU) with 5 channels per module that saves space at a low cost per channel for a wide range of applications requiring numerous precision power supplies. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2130A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2130A suitable for noise sensitive applications such as quantum computing as well.
-
product
Current Source
M151
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
product
High-Voltage Power Amplifier / Piezo Driver
Model 2210
Trek’s Model 2210 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and auto recovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.
-
product
PXI/PXIe Relay Driver Module, 64-Channel, 5V Relay Supply
42-411A-001
The 40-411A-001 (PXI) and 42-411A-001 (PXIe) are 64-channel relay drivers and are part of a range of modules with 16, 32, 48 or 64 channels of low side current drive. To use the module, simply connect a positive voltage source to one side of the relay coil and the other side to an output channel. Each output is capable of sinking up to 1 A of continuous current.
-
product
Portable Electrical Management Systems
EMS-LCHW30
Progressive Industries Portable Electrical Management Systems (EMS) provide full RV protection against all adverse power conditions. You will feel secure with multi-mode surge, voltage, polarity and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: Voltage(s), current, frequency, error code, and previous error code (if applicable). Replacement parts are simply plug-and-play, making repairs quick and easy. As with our portable models, the computer is driven by state of the art microprocessors. Should the software ever change, EMS owners can receive a free upgrade at no cost.
-
product
General Purpose Radiation Survey Meter/Geiger Counter
Rad 100™
The RAD 100™ is a general purpose radiation survey meter/geiger counter that detects and measures alpha, beta, gamma, and X-radiation. It is intended for personal safety and educational purposes. Like the popular Radalert® 100X, the RAD 100™ features a 3-second update on its digital liquid crystal display (LCD). The LCD shows the current radiation level in your choice of microSieverts per hour (SI units) or mR/hr for gamma radiation measurements. For mixed sources (alpha, beta, gamma) the CPM mode is recommended. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours. A red LED blinks and a beeper chirps with each count (the chirp can be muted). This is a professional instrument that is also easy to learn to use and to operate, and carries the industry leading Medcom warranty (2 years overall limited to 1 year on the GM sensor). Many instruments designed by the Medcom team are still working perfectly after 30 years of use, so this instrument should provide a lifetime of useful information.
-
product
Manual Oscillators
MOS-01, -01A
The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.
-
product
Arc Ingintion Tester
The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.
-
product
DC Bias Current Source
DU2020/2030/2040
Delta United Instrument Co., Ltd.
Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display
-
product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.
-
product
AC / DC Combined High Voltage Test Set
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
product
Source Measure Units and LCR Meters
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
product
PoE Tester
PE-100
The PoE Tester/Power Monitor is designed for testing standard PoE and measuring power of PoE systems, by performing both PSE (Power Source Equipment) detecting and PSE/PD (Powered device) inline testing. Compliant with IEEE802.3 af, 802.3at standard and 802.3bt ultra 4-pair up to 60W-100W. PSE detecting display PoE type (af or at), power source (Endspan or Midspan) and perform a load test for voltage drop with REV LED indicates a reversed power. Inline PSE/PD testing-measure and display in rotation between voltage (Volts), current(Amps) and power(Watts) via dual 4 digit 7 segment LEDs which provides voltage available, current flowing and how much power an PD actually need ensure sufficient power for PD to make the PoE is sustainable.
-
product
Source Measure Unit (SMU)
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measurement units (VMU, CMU).
-
product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
product
3U OpenVPX Multichannel Discrete I/O Board
68DT1
The 68DT1 is a 3U OpenVPX™ board featuring up to 96-Channels of Standard Functionality (SF) DT1 module-type or Enhanced Functionality (EF) DT4 module-type Discrete I/O functions [foptioned, factory configurable].48-Channels are dedicated as input (voltage or contact sensing with programmable, pull-up/pull-down current sources). An additional 24 or 48-Channels are programmable for either input or output (current source, sink, or push-pull) switching up to 500 mA per channel from an applied 3 – 60 V external VCC source (or sink to ISO-GND). The 68DT1 can sense broken input connections and whether an input is shorted to +VCC or to ground. Additional features of the DT4 EF are listed below. The 68DT1 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for pull-up resistors or mechanical jumpers.
-
product
Network Tester
ZhangZhou Weihua Electronic co.,ltd
There is nothing worse than running your drops only to learn that you have a fault in one of the cable runs. Get it right the first time, get it right by choosing and using the right LAN Cable Testers. We offer a variety of cable testers, which are a must have to quickly and easily verify the integrity of Ethernet twisted pair cables. Our LAN testers will test twisted pair cables for open pairs, shorted pairs, reversed pairs, crossed pairs and split pairs. Network cable testers vary in complexity and price, but a basic tester consists of a source of electrical current and a measuring device. After that, cable testers vary in complexity and ability to do various testing.
-
product
Solar Array Simulator
Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.
-
product
HV-Test System for Capacitor Packages
The system is used to characterize the leakage currents of capacitor packages. LXinstruments implemented a project-specific PCBA for the required HV switching. The measurement technology consists of Keithley source meters and USB based devices. The DUT adaptation with safety technology was realized in cooperation with ATX.
-
product
Dual Mobile Comm DC Source w/ Battery Emulation
66319B
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a rack box) and eliminates the need for two separate power supplies.
-
product
Transconductance Amplifier
1620A
The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.
-
product
Multifunction Calibrator 15 ppm Basic Accuracy
MC142
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
product
Power Sources
GF303
Beijing GFUVE Electronics Co.,Ltd.
GF303 Program-controlled three phase AC standard power source is a high precision three phase AC standard current source and AC standard voltage source.
-
product
Thermalyze Extension for Steady State Analysis
Lock-In
Steady-state thermography is limited to detecting hot spots that heat up a minimum of 100 mK (0.100°C). This may be useful for locating shorts on high-power devices, but is inadequate for detecting low power defects such as semiconductor device leakage current or short circuit with very low or very high resistance. Steady-state thermography also suffers from poor spatial resolution as the heat from localized hot spots diffuses rapidly, blurring the location of the heat source.
-
product
Capacitor for DC Filtering
FIL1
Lifasa - International Capacitors, SA
FIL condensers are specially designed for use in direct current sources and their functions are to filter the alternating output ripple and protect the line from instantaneous peaks and surges of tension.