- Pickering Interfaces Inc.
product
PXI Dual RF Attenuator, 2.3GHz
41-181-022
The 41-181 Programmable Attenuator Module is available with either one or two independently programmable attenuators in a single width 3U PXI module. Each attenuator uses high reliability mechanical switches to operate binary weight attenuator pads, providing attenuation values from 0 to 63dB in 1dB steps. Attenuator operating time is typically just 5ms, ensuring fast setting times.
-
product
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV
RP4060
+/-60V offset permits the DC signal to be displayed in the vertical center of the oscilloscope grid with a high-sensitivity gain setting (maximum +/-800mV dynamic range).
-
product
Antennas
The PLA-R and PLA-T are active, battery powered receive and transmit loop antennas for the frequency range 9 kHz - 30 MHz intended for radiated emission testing (PLA-R) and site validation: Normalized site Attenuation, Shielding Effectiveness (PLA-SET consisting of PLA-R and PLA-T)
-
product
Power Measurements Conditioner
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
product
Voltage Variable Attenuators
Voltage variable attenuators (VVAs) that offer up to 60 dB of attenuation across a broad range of frequencies from 400 MHz to 18 GHz. These voltage variable attenuators are frequently used in applications such as electronic warfare, instrumentation, point-to-point and point-to-multipoint radios, fiber optic and broadband telecom, microwave radio and VSAT, military radios, radar, ECM, SATCOM and sensors, and R&D.
-
product
Variable Optical Attenuator
Shenzhen Golight Technology Co.,Ltd
Variable optical attenuator uses high-precision attenuation control components, and combines a selfdeveloped embedded data processing platform and precise calibration process, can be provided with maximum 60dB optical power attenuation and optical power monitoring function. Real-time display of input and output optical power.
-
product
MS-M 26-Pin RF Cable Assembly, Female to Unterminated, 2m, RG316 Cable
40-979A-526-3-2m-FU
This 2m long MS-M RF 26-Pin cable assembly is constructed from RG316 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 68dB/100m at 500MHz. Screwlocks are provided to secure the MS-M connector to the mating connector.
-
product
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory.
-
product
Passive Imaging & Radiometers
PMMW
A low attenuation atmospheric window from 80-110 GHz (W Band) makes this band an ideal candidate for PMMW systems. Passive imagers operate by detecting naturally emitted thermal (black body) radiation from an object. Products available up to 345 GHz.
-
product
Waveguide Tunable Attenuators
*Low Insetion Loss*Full Waveguide Band Coverage*Precise Adjustment*High Maximum Attenuation
-
product
Digital Attenuators
Macom Technology Solutions Holdings Inc.
Digital Step Attenuators (DSA)are offered in up to 6 Bit control with lowest step size of 0.5 dB covering DC to 40 GHz. MACOM's DSAs can be controlled with serial and parallel control allowing for best implementation for our customers. These products exhibit low insertion loss and high attenuation accuracy and are offered both GaAs and Silicon (SOI) processes and are offered in both packaged and bare die form factors.
-
product
High-Performance USB-Controlled PLL Synthesizers
Rugged, SMA-connectorized designs that support a USB 2.0 interface with a PC supplying DC power and GUI command control. They cover a broad range of frequency bands from 25 MHz to 27 GHz. These USB-Controlled PLL Synthesizers deliver output attenuation that is adjustable up to 50 dB in 1 dB steps and high output power levels ranging from +10 dBm to +19 dBm typical. Phase noise is as low as -108 dBc/Hz at 100 MHz offset and phase locked speed is 1 msec typical.
-
product
Differential Probe
DP-60HS
*High Sensitivity Model: x 1, x 5, x 10 Attenuation*1 MΩ // 10PF Input Impedance*High Frequency Operation: x 1(30 MHZ), x 5(60 MHZ), x 10(60 MHz)*Especially For Low Voltage: x 1(7 Vp-p), x 5(35 Vp-p), x 10(70 Vp-p)
-
product
MS-M 3-Pin RF Cable to SMB, 0.5m
The MS-M RF 3-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 1.08dB/m at 400MHz. Screwlocks are provided to secure the MS-M connector to the associated product.
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Series Two Channel Low Pass Filter
SR600
Stanford Research Systems, Inc.
The SR600 series consists of three dual-channel instruments. Each instrument channel has a low-noise preamplifier, a precision high pass or low pass filter section, and an output amplifier. The filters are 8-pole, 6-zero elliptic-type with 115 dB per octave rolloff, 0.1 dB of passband ripple, and 80 dB of stopband attenuation.
-
product
PMC Compatible Wizard Interface
PMC-Wizard
The PMC-Wizard is intended for use in ultra high-speed bidirectional point-to-point data transmission systems. The primary application is to provide very high-speed I/O data channels for point-to-point baseband data transmission over controlled impedance media of approximately 50 Ω. The maximum rate and distance of data transfer is dependent upon the attenuation characteristics of the media, and the noise coupling to the environment
-
product
SHDE9F-DE9F-FX Flexray Cable, No Termination, 1M
198290-01
9-Pin, Female D-SUB to 9-Pin, Female D-SUB FlexRay Cable - The SHD9F-D9F FlexRay Cable connects FlexRay interfaces to devices, breakout boxes, other interfaces, and accessories. This cable meets FlexRay cabling specifications and is compatible with all NI-XNET FlexRay interfaces. It offers 82 dB/km attenuation with no termination. The cable’s impedance is 100 Ω, 148.94 Ω/km at 20 °C resistance, and 5.2 ns/m delay. The cable features four 26 AWG twisted pairs and dedicated pairs for FlexRay Bus A and Bus B.
-
product
10MHz Multi-Waveform Signal Generator
Model MSG10M
- Sine, Triangle, Square Output Waveforms- Easy Control of Generator Frequency- Frequency Readout in Hz, KHz, MHz- Output Attenuation upto 40dB- Low Cost
-
product
Direct Reading Attenuator
DAXE
DAXE Millimeter-Wave Direct Reading Attenuator is a measurement instrument for signal level setting or loss measurements in waveguide networks. It also can be used for calibration of other attenuation measurement instruments. Direct Reading Attenuators have rotary-vane design. The value of attenuation is determined by rotation angle of resistive film with respect to the waveguide channel. Attenuation value does not depend on of frequency.The Attenuators are provided in waveguide bands between 18 GHz and 225 GHz.
-
product
Normalised Site Attenuation
NSA
Normalised Site Attenuation (NSA) is measured in accordance with CISPR 16-1-4 and ANSI C63.4 in semi and fully anechoic environment.
-
product
EDFA
SPA-2-4X22-WDM EYDFA
Hangzhou Softel Optic Co., Ltd.
*Single/dual input for choice, built in optical switch for dual input, the switching power can be set by the button in the front panel or by web SNMP.*Output adjustable by buttons in the front panel or web SNMP, the range is down 4dBm*Maintenance function of one-time downward attenuation of 6dBm by buttons in the front panel or web SNMP, to facilitate the optical fiber hot-plug operation without turn off the device*Multi- ports output, can built in 1310/1490/1550WDM.*Standard RJ 45 port for remote control, we can provide output contract and web manager for choice, and also plug-in SNMP hardware can be reserved for update.*With laser key to turn on/off the laser.*With RF test function.*Adopts JDSU or Oclaro Pump laser*Led displays the working condition of the machine*Dual power hot plug power supply for choice, 90V~250V AC or -48V DC
-
product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Manual Attenuator (Waveguide)
Manual control waveguide attenuators in both variable (continuous) or stepped in a variety of frequencies, attenuation values / step sizes and power levels
-
product
RF Attenuators
Bird manufactures a broad spectrum of devices from 2 W to 4000W. Our resistive product portfolio includes air-cooled, water-cooled, oil-dielectric, convection cooled, and conduction cooled RF attenuators with a wide range of connectors and attenuation values.
-
product
6, 8 GHz, 4 Channel Programmable Attentuator
QPA8, PA8
This device has low impedance mismatch, high bandwidth, wide dynamic range and is capable of rapid state change. The QPA8 can be an attractive alternative to either the manually operated microwave attenuator switches, which are expensive and are switched very slowly, or the relay attenuators which are expensive and wear out quickly. Attenuation is controlled in standard steps of 0.0625 dB. The 10 bit programmable range results in the full 210=1024 steps yielding a dynamic range of 0 to 63.9375dB. Non-standard custom step sizes are available.
-
product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Variable Attenuators
Wuhan Sunma Technology Co., Ltd.
SunmaFiber offer optical variable attenuator is used for continuously variable optical signal attenuation. As the attenuator is used in the laser system for the on-line testing, there can be used in the digital system of communication devices (such as:PHD, SDH) and also in the system of adopting analog modulation (CATV).
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.