Filter Results By:
Products
Applications
Manufacturers
Contact Resistance
opposition to the flow of heat or electricity within a connection.
- Virginia Panel Corporation
product
Coax, Contact, ITA, 20 GHz, RG 223, Crimp, 90 Series Modules only
610102117
Primary mating contact 610102116. (May mate with other ITA contacts, as well.)20 GHz coax contacts have an impedance of 50 Ohms and a current rating of 5 amps.It is recommended to use SF142 to achieve 20 GHz and RG223 to achieve 12 GHz.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 20 GHzVSWR 1.15 + .01 (f) GHz w/ RG142 (8 GHz)1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG 223 Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Signal, Contact, Receiver, TriPaddle, 10 Amp, 14-18 AWG
610110177
Primary mating contact 610110113. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, Twin Female
610138200
Primary mating contact 610138118. (May mate with other Male Adapter and ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BeCu/PhBrzContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAvg Mating Force(lbs) 0.24
-
product
Low Resistance Meter
MMR-640
The MMR-640 meter is designed to measure very low resistance of resistive objects. This product is made to be used in power plants, railways and maintenance companies to measure resistance of:*breakers, contacts,*earthing conductors, equipotential bondings,*welded and soldered connections,*bolted connections,*and other resistive objects.
-
product
PXI Single 55x8 Matrix 1-Pole Switching
40-538-021
The 40-538 ultra high density matrix module is configured as a Single 55x8 reed relay matrix with 1-pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e8 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Mini Coax, Contact, ITA, RG178
610103157
Mini Coax, Contact, ITA, RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Center conductor – BeCuShield – BrassContact Plating Shield 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50C to +105CInsulation Resistance 1000 MΩ min.
-
product
Electric Testing
Our Capabilities*Dielectric Withstand*Hi-Potential Testing*Voltage Drop*Contact Resistance*Gate Leakage*Insulation Integrity*Dielectric Integrity
-
product
Micro Coax, Contact, Receiver, RG178
610140102
Primary mating contact 610141102. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG178Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Micro-Ohmmeter
MR 300 C-A
The MR300C-A micro-ohmmeter enables you to perform highly accurate resistance measurements at objects with an extremely low resistance such as cables, contacts, fuses, power connections, graphite, carbon and metal samples. In the lowest measuring range of 100 µΩ the resolution is 10 nΩ.
-
product
PXI Dual 44x4 Matrix, 1-Pole Switching
40-536-021
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Network Cable
Maximum speed 50 micron GOLD-PLATED contacts ensures the maximum speed is achieved through low resistance and signal degradation.Heavy Duty durability Lasts up to 10 times longer than other cables due to advanced protection against atmospheric corrosion and low friction.Network support CAT 5e cable will support Ethernet, Fast Ethernet, and Gigabit Ethernet. CAT 5e Cable is completely backwards compatible, and can be used in any application in which you would normally use CAT 5 cable.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Micro Coax, Contact, Receiver, RG179
610140103
Primary mating contact 610141103. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 75ΩFrequency Range DC – 2 GHzVSWR 1.39 @ 2 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG179Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Instrument Transformer Calibrators
MRL 22
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Mini Coax, Contact, Receiver, RG316
610104114
Primary mating contact 610103115. (May mate with other ITA contacts, as well.)*This contact available as a patchcord only. Please select link below to configure a patchcord.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance ≤ 5 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, 22-28 AWG, 50µ” Au, Crimp
610138116
*Please note: The difference between this p/n and 610138216 is the amount of gold plating. See below.P/n 610138116- 50µ" AuP/n 610138216- 30µ" AuPrimary mating contact 610138112. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BeCuContact Plating 50µ" Au over 100µ" NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force(lbs) 0.24
-
product
KV CAPS
500 V
Macom Technology Solutions Holdings Inc.
The MACOM KV CAPSTM Si high voltage capacitors feature very high working voltage ratings, very low loss and excellent stability by virtue of their novel internal construction and very high-quality dielectric layers. These capacitors are available as unpackaged chips. The chips have gold bonding surfaces on both terminals to enable excellent bonding and minimum contact resistance.
-
product
Clamp Multimeters
Clamp Meter is a 5 function, 9 range auto-ranging unit engineered to measure AC Current (40-400A), AC/DC Voltage (400/600V), Resistance (400/4000O), and Continuity. Similar to digital multimeters, clamp meters offer a large range of functions and include LCD screens to display results but they offer the additional unique ability to measure current without having to contact live conductors.
-
product
Contact Resistance Tester
Weshine Electric Manufacturing Co., Ltd
The loop resistance tester is used to test the conductive loop resistance of various switchgear, and the test current shall not be less than 100A. Due to the oxidation of the contact surface, poor contact tightening and other reasons, the contact resistance increases. When a large current flows, the temperature of the contact point increases, which further accelerates the oxidation of the contact surface and further increases the contact resistance.
-
product
Dynamic Contact Resistance Meter
Dynamic contact resistance measurements are necessary to understand the condition of the arcing contacts of the circuit breaker. Static contact resistance measurements do not give us information related to erosion of arcing contact, misalignments of the contact, and damages to the driving mechanism.
-
product
PXI 6U PXI High Density Matrix, 132x8 1-Pole
45-541-001
This 6U PXI Reed Relay Matrix Module is an ultra high-density reed relay matrix available in 132x8 format with 1- pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e9 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Automated Functional Switch Tester
UST
UST is a functional switch tester. It tests switches by running them automatically and in the process it measures contact resistance, contact bounce, and activation force. Other performance criteria can be added.
-
product
Milliohm Meters & Microhm Meters
Shanghai Beha Electronics Co., Ltd.
Makes measurements by passing a constant current through the device under test (generally a conductor, contact or low resistance) and measuring the voltage across it. It has visual LED checks for excessive; potential lead resistance (RP) and current lead resistance (RC). Should the instrument become too warm, the temperature sensor will shut down the current (ISCOFF).
-
product
Probe Head
cViper
cViper™ is an ultra-fine pitch probe head for RF and high speed digital WLCSP. cViper is ideal for lab and large volume production test for precision analog, RF, sensors and mobility devices. Low loop inductance and high bandwidth up to 27 GHz, cViper offers low and stable contact resistance for singulated devices or wafer-level test. A variety of contact materials to optimize performance are available with device pitch down to 100 µm.
-
product
Digital Circuit Breaker Analyzer
CT-8000 S3
The CT-8000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.
-
product
Chilled Mirror Transmitter
DewTrak II
The DewTrak II uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance thermometer to accurately measure that temperature. Outputs include 4 to 20mA, 0 to 5 Vdc, or 0-10Vdc and an RS232 serial port as well as electrically isolated relay contacts.
-
product
Cable Fault Locator System
Kvtester Electronics Technology Co.,Ltd
To test the HV arcing fault of cable, earthing high &low resistance, short circuit and breakage of the cable, poor contact, etc. If equipped with fault locator, it can decide the exact broken position of the cable ,applies to power cable in various type, voltage and communication cable
-
product
PXI Ultra High Density 64x2 2-Pole Matrix
40-533B-032
The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Miniature Two-Point Probe Set
PRF-922B
The PRF-922B Miniature Two Point probe accurately measures point-to-point resistance of small areas. Like Prostat's PRF-912B Miniature Concentric Ring, the PRF-922B is capable of measurements up to 1.0x1012 ohms. Built-in distance stops provide consistent electrode to sample pressure for developing repeatable measurements. Use the PRF-922B to measure small material samples, hard to assess molded areas, edges of parts, tray or tape cells and other very small objects and surfaces. The assembly is supplied with replaceable conductive electrode covers to enhance contact resistance on irregular surfaces and composition materials. Thus, measurements may be made with either the gold plated electrode contacts, or via conductive rubber covers.
-
product
Dual 16x6 1-Pole High-Density PXI Matrix Module
40-520-303
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.