Filter Results By:
Products
Applications
Manufacturers
Reflectance
fraction of the electromagnetic energy.reflected.
-
product
Scatterometers/ Thin Film Metrology Systems
LittleFoot Series
The n&k LittleFoot-CD, and LittleFoot-CD450 are DUV-Vis-NIR scatterometers/thin film metrology systems, based on polarized reflectance measurements (Rs and Rp) from 190nm to 1000nm, with microspot technology. The systems in the LittleFoot-CD Series determine thickness, n and k spectra from 190nm-1000nm of thin films, as well as depths, CDs, and profiles of trenches and contact holes.
-
product
Retro-Reflectometer
The visibility is an important factor for road markings, traffic signs, road studs as well as high-visibility material such as warning clothes and Heavy good vehicles (HGV's) contour safety marking.The measurement of retroreflectivity is essentially a measurement of the reflectance of material under specified geometrical and spectral conditions. Instruments are available for measuring the retroreflectivity of various reflection materials.
-
product
Single Fiber Aligner
1100
The 1100 Single Fiber Aligner uses patented fiber alignment concepts to produce virtually instantaneous temporary couplings for OTDR, dispersion, or any other optical fiber or component test that requires a fiber-to-fiber connection. It delivers low loss, low reflectance couplings on the first try virtually every time, without the need for test instrument feedback. As a result, temporary coupling times are minimized and manufacturing costs are reduced without compromising product quality.
-
product
VNIR Hand-held Spectroradiometer
HandHeld 2 Pro
Analytical Spectral Devices, Inc.
The FieldSpec HandHeld 2 Pro hand-held spectroradiometer offers greater sensitivity over the standard HandHeld 2 spectroradiometer model, aiding spectral measurements for applications with low reflectance characteristics such as water surfaces. Wherever there is a need for enhanced sensitivity, faster collection rates, high signal to noise performance, the HandHeld 2 Pro is the low cost VNIR spectroradiometer of choice.
-
product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
product
DOI / Haze Meter
807
TRICOR’s Hazer Meter and DOI is ideally suited for measuring flat, non-textured high reflectance surfaces. The Model 807A Haze Meter design is in accordance with ASTM E430 and ASTM D5767 (method A) and is used to measure ±3 degrees around the specular lobe centered at 30 degrees in approximately 220 increments. That’s an angular sample size of 1 sample per 1.6 minutes of arc! This allows differentiation between samples with very small differences in reflectance characteristics. Verified replacement for the older Hunter Dorigon II haze meter unit.
-
product
Flatness Mirror
10773A
The Keysight 10773A Flatness Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror, used in the 5530 Laser Calibration System, measures flatness in applications such as surface plate calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10773A.
-
product
UV-Vis Double Beam Research Spectrophotometer
UVD-3400
UVD-3400 has an excellent performance blazed holographic grating optimized and optional reflectance attachment CT-type Monochromator and reduces stray light and widen the photometric range. Wavelength range: 190 nm – 900 nm ; Spectral bandwidth: 2nm
-
product
FiberPulse OTDR
XO1
FiberPulse OTDRs send pulses down fiber optic networks from one end of the fiber, displaying a trace and reporting all detected events such as splices, connectors, macrobends and fiber ends and breaks. The total fiber length is reported along with name, location, loss and reflectance of detected events. The intuitive keypad design features integrated shortcut keys designed for quickly positioning and analysing events. Another feature of this unit is the Live Optical Signal Detect Function, which tests if the fiber is live before sending the pulse, this can effectively prevent accidental damage to the OTDR and attached communication equipment.
-
product
Gloss & Reflectance
Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.
-
product
Hybrid Diffuse Reflectance Spectrometer
Poly602™
Solar Light has developed the fastest performing DRS instruments on the market, keeping product research, formulation and clinical testing in mind. HDRSplus™ software is designed specifically for a clinical testing laboratory environment and simplifies all HDRS calculations.
-
product
Diamond Testers
Napco Precision Instruments Co
Jewelry Tester is an account of full wavelength spectrum analyzer. It can appraise true or false and whether or not dyed of jewelry. its wavelength range from ultraviolet to near infrared. it can test spectral reflectance curve of hundred kinds of jewelry effectively.
-
product
Radiative Transfer Numerical Model
HydroLight
The HydroLight radiative transfer numerical model computes radiance distributions and related quantities (irradiances, reflectances, diffuse attenuation functions, etc.) in any water body.
-
product
Glossmeter
480
Quickly and accurately measure and record Gloss, % Reflectance & Haze measurements on a wide range of materials, including paint, plastic, ceramic or metal with the Elcometer 480 Glossmeter.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Spectroscopic Reflectometry
Measure reflectance of flat or curved samples with smooth or rough surface.
-
product
Lens Measurement Spectrophotometers
LINZA 150
LINZA 150 spectrophotometer is designed for broadband transmittance and reflectance measurement of lenses and lens assemblies (objectives) ensuring that only perfect lenses are approved for lens assemblies, delivered to customers or meet specs provided to your lens supplier. The instrument is perfectly suited for both routine lens measurements and sophisticated improvement of lens production technology: Fast on-axis transmittance measurement of individual convex/concave lenses. Fast on-axis transmittance measurement of lens assemblies (objectives). Unattended on-axis and off-axis reflectance measurement of individual lenses providing measurement data virtually from any area on lens surface (both convex and concave). Ideal for fine-tuning of deposition technology used to produce coatings on lenses.
-
product
Spatial Heterodyne Surface Chemical Agent Detector
SHSCAD
Wide area, high areal coverage rate surface contaminant detection via LWIR reflectance spectroscopy employing eye safe broadband quantum cascade lasers (QCLs) and a high-speed spatial heterodyne spectrometer (SHS) in a handheld sensor package (~ 10,000 cm3, 10 lb).
-
product
Reflection/Transmission Test Chamber
CHTR-100
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
product
Bar Code Verifier
TP140B Report Printer
The TP140B Report printer allows for printing of inspection reports from your Inspector series bar code verifier. The printer provides a simple report that will have a line for each bar code inspected. Note: The Verifier Computer Interface Report (VCIR) is required if you need the Scan Reflectance Profile (SRP).
-
product
Thermal Conductivity Analyzer
TCi
The default C-Therm TCi Thermal Conductivity Analyzer employs the Modified Transient Plane Source (MTPS) technique in characterizing the thermal conductivity and effusivity of materials. It employs a one-sided, interfacial heat reflectance sensor that applies a momentary constant heat source to the sample. Typically, the measurement pulse is between 1 to 3 seconds. Thermal conductivity and effusivity are measured directly, providing a detailed overview of the heat transfer properties of the sample material.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
SRA01-Albedometer
Hukseflux Thermal Sensors B.V.
SRA01 albedometer is an instrument that measures the solar albedo, or solar reflectance, and net solar radiation. It is composed of two second class pyranometers with thermopile sensors, the upper one measuring global radiation, the lower one measuring reflected solar radiation. It complies with the latest ISO and WMO standards. SRA01 can be connected directly to commonly used datalogging systems.
-
product
Spectrometer & Colorimeter
Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.
-
product
Diffuse Reflectance Sphere
DRS100
Mobile displays are used in a variety of ambient lighting environments. The evaluation of mobile displays under diffuse illumination conditions is critical to the understanding of display performance in the real world, as mobile displays are used in a wide range of ambient lighting environments. The DRS100 is purpose-made to completely characterize the diffuse reflectance properties of mobile displays, providing uniform hemispherical illumination.
-
product
Turning Mirror
10772A
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
product
Transmission / Reflection Measurement
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
product
Hybrid Diffuse Reflectance Spectrometer
Mono602™
Solar Light has developed the fastest performing DRS instruments on the market, keeping product research, formulation and clinical testing in mind. HDRSplus™ software is designed specifically for a clinical testing laboratory environment and simplifies all HDRS calculations.
-
product
Flatness Accessory Kit
55282A
The 55282A Flatness Accessory Kit is composed of an 10759A Footspacing Kit and two 10773A Flatness Mirrors. The footspacing kit provides three precision baseplates, with 50.8 mm (2 in), 101.6 mm (4 in), and 152.4 mm (6 in) pad spacing respectively, that minimize the grid setup and data accumulation time required for plate calibration. The flatness mirrors provide 100 percent reflectance and turn the direction of an incoming laser beam 90 degrees.
-
product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.