Beijing KeHuan Century EMC Technology Co,.LTD
Beijing Kehuan Century Electromagnetic Compatibility Technology Co., Ltd. is a company engaged in electromagnetic interference ( EMI ) It is a high-tech enterprise engaged in technical research. The electromagnetic compatibility technical solutions and EMI Receiver series products provided by the company are very popular among domestic enterprises. The products are widely used in various electromagnetic compatibility testing fields. Enterprises, research institutes, various universities and production enterprises provide reliable and stable electromagnetic compatibility testing solutions.
- 010- 64363390
- 010-69753578-588
- bjkhsj@126.com
- 2nd Floor, Building B, Hongfu Science and Technology Park Innovation Center
North Seven Town, Changping District
Beijing, 102209
China
-
product
Radiated Immunity Test System
Beijing KeHuan Century EMC Technology Co,.LTD
Radiation Immunity Test System.
-
product
Receiver
Beijing KeHuan Century EMC Technology Co,.LTD
A device or apparatus that receives electrical signals, waves, or the like, and renders them perceptible to the senses, as the part of a telephone held to the ear, a radio receiving set, or a television receiving set.
-
product
Lightning Surge Generator
STT-LSG-7K16A
Beijing KeHuan Century EMC Technology Co,.LTD
The lightning surge generator STT-LSG-7K16A provides a common basis for evaluating the performance of equipment power lines and internal connecting lines when they are subjected to high-energy transient interference from switching and natural lightning strikes. The performance meets the requirements of IEC61000- 4-5 and GB/T17626.5 standards.
-
product
Artificial Power Supply Network
KH3762
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
product
Cycle Drop Simulation Generator
Beijing KeHuan Century EMC Technology Co,.LTD
Cycle drop simulation generator
-
product
Artificial Power Supply Network
KH3760
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
product
Manual Power Supply Network Manual
KH3766
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Vehicle Electromagnetic Field Test System
Beijing KeHuan Century EMC Technology Co,.LTD
Vehicles are the daily means of transportation for our public, and the electromagnetic pollution in vehicles has received more and more attention from the public. The newly revised mandatory standard GB27630-201X "Air Quality Evaluation Standard for Passenger Cars" intends to require the electromagnetic field in the vehicle as one of the indicators. The measurement method measures the magnetic field strength in the vehicle. Within the frequency range of 10Hz-400kHz, the electromagnetic field measurement results should meet the requirements of the public limit of electromagnetic exposure in GB8702-2014.
-
product
Antenna
Beijing KeHuan Century EMC Technology Co,.LTD
Antenna is adjusted using the receiver, use, testing, measurement, etc.
-
product
Electromagnetic Environment Online Monitoring Systems
OS Series
Beijing KeHuan Century EMC Technology Co,.LTD
Beijing KeHuan Electromagnetic Environment Online Monitoring Systems
-
product
Cycle Voltage Drop (Rise) Simulator
STT-CSS-20P1
Beijing KeHuan Century EMC Technology Co,.LTD
*Using 2 The regulator, and the rated voltage adjustable automatic voltage regulator, power fluctuations avoid adversely affecting the test results. Simulate the test under 110V power supply. It can simulate the fluctuation of the power grid under extreme conditions (such as high or low power supply voltage in remote areas).
-
product
Voltage Probe
KHZ43201
Beijing KeHuan Century EMC Technology Co,.LTD
The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.
-
product
EMI Receiver
KH3931
Beijing KeHuan Century EMC Technology Co,.LTD
* Detection frequency range: 9KHz-30MHz * Frequency stability: 1X10-6 * Frequency resolution: (9kHz ~ 150kHz): 30Hz; (150kHz ~ 30MHz): 1kHz * Test error: ±2dB * Corresponding characteristics of pulse: in line with national standard GB/T6113.1-1995 * Detection time constant: in line with national standard GB/T6113.1-1995