IRIS Instruments
We bridge geophysics and digital with unmatched equipment that measure, process and interpret field data.
- +33 2 38 63 81 00
- info@iris-instruments.com
- 1 avenue buffon
Orléans, 45100
France
-
product
Syscal Pro
The Syscal Pro is an all-in-one multinode resistivity and induce polarization sounding and profiling system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250 W internal transmitter which make it the more powerful system of the Syscal range. Compact, easy-to-use and field proof, the Syscal Pro measures both resistivity and chargeability. It is ideal for environmental and civil engineering applications such as depth-to-rock determination, weathered bedrock mapping. With a maximal output voltage of 2000Vpp, the Syscal Pro is very adapted to detect deep fault in fractured aquifers or to characterize the depths and thickness of the groundwater aquifers.
-
product
V-FullWaver
The V-FullWaver systems were specifically developed for precise full waveform time domain Induced Polarisation, Resistivity and SP measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording. The V-FullWaver is a dual channel Induced Polarisation, Resistivity and SP receiver. Continually recording at 10ms sample rate provides a full waveform record. It can be synchronized on the GPS PPS signal, allowing an easy process of the signal. Data on the memory can be downloaded directly on a simple USB stick from all the Fullwavers.
-
product
Receiver
Elrec Pro
The Elrec Pro is a 10 channel Induced Polarisation (IP) and Resistivity receiver designed to improve productivity when recording deep profiles and soundings. Beside the classical arithmetic and logarithmic modes, ELREC Pro also offers a Cole-Cole mode and twenty fully programmable windows for a higher flexibility in the definition of the IP decay curve.
-
product
VLF Receiver
T-Vlf
The VLF receiver is specially designed for high productivity surveys, in ground water and mining exploration. No orientation of the operator with respect to the direction of the transmitter is required since three magnetic sensors measure the components of the VLF field. Tilt or horizontality of the sensor unit is neither required since two inclinometers correct for tilted position.
-
product
Syscal R2
The Syscal R2 unit is a high-power system designed for DC electrical surveys applied to groundwater exploration, environmental studies, civil engineering, structural geology investigation and mineral exploration.
-
product
Full Wave Recorder
I-FullWaver
The I-FullWaver systems were specifically developed for precise full waveform time domain induced polarisation, Resistivity and self-potential measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording.
-
product
Syscal Junior
The Syscal Junior is an all-purpose resistivity and induced polarization sounding and profiling system for environmental applications. The system is supplied as a standard sounding system capable of recording two measurements simultaneously, perfect for performing offset Wenner sounding arrays. The output current is automatically adjusted (automatic ranging) to optimize the input voltage values and to ensure the best measurement quality.
-
product
Standard Transmitter
Tipix 2200
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
product
Full Wave Recorder
V-FullWaver
The V-FullWaver systems were specifically developed for precise full waveform time domain Induced Polarisation, Resistivity and SP measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording.
-
product
Syscal Pro switch
The Syscal Pro is an all-in-one multinode resistivity and induce polarization imaging system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250W, 2000Vpp internal transmitter which make it the more powerful system of the Syscal range. This system allows to perform up to 10 measurements at a time and its switching board allow to work for 48 (Switch-48) up to 120 (Switch-120) electrodes.
-
product
Syscal Kid
Specifically designed for very shallow, high resolution resistivity and induced polarization sounding and profiling, the Kid is the most compactof the Syscal range whilst retaining the well-known reliability and measurement accuracy of its counter parts.
-
product
Syscal Kid Switch
Specifically designed for very shallow, high resolution resistivity sounding and profiling, the Kid is the most compact of the Syscal range whilst retaining the well-known reliability and measurement accuracy of its counter parts.
-
product
Regulated Transmitter
TIP One
The TIP One is purposely designed for shallow induced polarisation or Resistivity sounding investigations. The TIP One injects a regulated current or regulated voltage into the ground via a simple 12V battery.
-
product
Regulated Transmitter
VIP 4000
The VIP series of Electrical transmitters are purposely designed for deep induced polarisation or Resistivity sounding investigations. The Vip injects a regulated current into the ground.
-
product
Syscal Deep Marine
In fresh water environment, the standard Syscal Pro can be used for marine resistivity profiling. However, in highly conductive environment, a modified variant with higher current output is required.